High Temperature Muffle furnace
Description
Model:LT 5/12/B410
with integrated process documentation
Brand: Nabertherm
Origin: Germany
>>Contact us>>
1.Scope of Supply
Electrically heated muffle furnace with
Controller B410
Integrated processdocumentation
2.Defined Application
The furnace had been designed for preheating or ashing in air.
Only materials with known characteristics and melting temperatures may be used. Check the material safety data sheets if necessary.
Use of the furnace for any other purpose whatsoever such as processingproducts other than those intended or handling hazardous substances orsubstances posing a health hazard constitutes improper use and must be agreed upon with Nabertherm.
Operating the furnace with explosive gases or mixtures, including explosive gases ormixtures created as a result of heating/drying, is prohibited.
This furnace features nosafety technology for processes which produce combustiblemixtures, for example debinding.If the furnace is still used for such processes despite this fact, the concentration of organicgas mixtures in the furnace must never exceed 3% of the lower explosion limit (LEL). Thispre-requisite applies not only to normal operation but, in particular, to exceptionalsituations such as process disruptions (caused, for example, by the failure of a power unit).You must ensure that the furnace is adequately ventilated and vented.
Do not open the furnace when it is hot. If thefurnace must be opened at high temperaturesreduce this time to the minimum possible.Wear protective clothing and provide sufficientroom ventilation.
Discolourations may occur on the stainlesssteel housing (especially when the hot furnaceis opened); these, however, do not affect thefunction.
3.Applied norms and specifications
3.1.General Norms and Directives
EN 61010-1
EN 61000-6-1, EN 61000-6-3
RoHSdirective 2011/65/EU
3.2.Customer’s specifications
Not considered
4. Technical specifications
Innerdimensions(wxdxh): 200 x 170 x 130 mm
Outer dimensions (WxDxH): 385 x 390 x 460 +205 mm
Volume: 5liter
Weight: 30 kg
Power rating: 2,4 kW
Supply voltage: 230 V, 1/N/PE, 50/60 Hz
Max. operating temperature: 1200 °C*
Heat-up time (without load): 75 min. to Tmax
(if connected at 230 V, 1/N/PE)
*Note:
Continuous operation at maximum temperature can lead to increased wear of the heating elements, thermocouples or isolation. We recommend operation at approx. 50 °C below the maximum temperature.
External dimensions vary depending on additional equipment. Exact dimensions on request.
5. Customized furnace design
Housing manufactured from high grade structured stainless steel
Dual shell housing
Exhaust air outlet in the furnace rear wall
Switching of the heating elements by electronic relay
Adjustable air inlet in the door
Door opening supported by springs
Lift-door with hot surface facing away from the operator
Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
Heating from two sides by ceramic heating plates with integrated heating wire which is safeguarded against fumes and splashing, and easy to replace
Thermocouple type S
Temperature uniformity of ΔT 20 K within the work space at temperatures > 800°C
6. Additional equipment in the scope of supply
Optional equipment and accessories are mentioned under poin